Analysis on ex-vessel loss of coolant accident for a water-cooled fusion DEMO reactor

Watanabe, Kazuhito; Nakamura, Makoto; Tobita, Kenji; Someya, Yoji; Tanigawa, Hisashi; Uto, Hiroyasu; Sakamoto, Yoshiteru; Araki, Takao*; Asano, Shiro*; Asano, Kazuhito*

Safety studies of a water-cooled fusion DEMO reactor have been performed. In the event of the blanket cooling pipe break outside the vacuum vessel, i.e. ex-vacuum vessel loss of coolant accident (ex-VV LOCA), the pressurized steam and air may lead to damage reactor building walls which have confinement function, and to release the radioactive materials to the environment. In response to this accident, we proposed three cases of confinement strategies. In each case, the pressure and thermal loads to the confinement boundaries and total mass of tritium released to outside the boundaries were analyzed by accident analysis code MELCOR modified for fusion reactor. These analyses developed design parameters to maintain the integrity of the confinement boundaries.