Yomogida, Takumi; Hashimoto, Tadashi; Okumura, Takuma*; Yamada, Shinya*; Tatsuno, Hideyuki*; Noda, Hirofumi*; Hayakawa, Ryota*; Okada, Shinji*; Takatori, Sayuri*; Isobe, Tadaaki*; et al.
Analyst, 149(10), p.2932 - 2941, 2024/03
In this study, we successfully applied a transition-edge sensor (TES) spectrometer as a detector for microbeam X-ray measurements from a synchrotron X-ray light source to determine uranium (U) distribution at the micro-scale and its chemical species in biotite obtained from the U mine. It is difficult to separate the fluorescent X-ray of the U L line at 13.615 keV from that of the Rb K line at 13.395 keV in the X-ray fluorescence spectrum with an energy resolution of approximately 220 eV of the conventional silicon drift detector (SDD). Meanwhile, the fluorescent X-rays of U L and Rb K were fully separated by TES with 50 eV energy resolution at the energy of around 13 keV. The successful peak separation by TES led to an accurate mapping analysis of trace U in micro-X-ray fluorescence measurements and a decrease in the signal-to-background ratio in micro-X-ray absorption near edge structure spectroscopy.
Li, W.*; Yamada, Shinya*; Hashimoto, Tadashi; Okumura, Takuma*; Hayakawa, Ryota*; Nitta, Kiyofumi*; Sekizawa, Oki*; Suga, Hiroki*; Uruga, Tomoya*; Ichinohe, Yuto*; et al.
Analytica Chimica Acta, 1240, p.340755_1 - 340755_9, 2023/02
Times Cited Count:4 Percentile:29.37(Chemistry, Analytical)no abstracts in English
Okumura, Takuma*; Azuma, Toshiyuki*; Bennet, D. A.*; Caradonna, P.*; Chiu, I.-H.*; Doriese, W. B.*; Durkin, M. S.*; Fowler, J. W.*; Gard, J. D.*; Hashimoto, Tadashi; et al.
IEEE Transactions on Applied Superconductivity, 31(5), p.2101704_1 - 2101704_4, 2021/08
Times Cited Count:1 Percentile:10.62(Engineering, Electrical & Electronic)A superconducting transition-edge sensor (TES) microcalorimeter is an ideal X-ray detector for experiments at accelerator facilities because of good energy resolution and high efficiency. To study the performance of the TES detector with a high-intensity pulsed charged-particle beam, we measured X-ray spectra with a pulsed muon beam at the Japan Proton Accelerator Research Complex (J-PARC) in Japan. We found substantial temporal shifts of the X-ray energy correlated with the arrival time of the pulsed muon beam, which was reasonably explained by pulse pileup due to the incidence of energetic particles from the initial pulsed beam.
Okumura, Takuma*; Azuma, Toshiyuki*; Bennet, D. A.*; Caradonna, P.*; Chiu, I. H.*; Doriese, W. B.*; Durkin, M. S.*; Fowler, J. W.*; Gard, J. D.*; Hashimoto, Tadashi; et al.
Physical Review Letters, 127(5), p.053001_1 - 053001_7, 2021/07
Times Cited Count:15 Percentile:80.44(Physics, Multidisciplinary)We observed electronic X rays emitted from muonic iron atoms using a superconducting transition-edge-type sensor microcalorimeter. The energy resolution of 5.2 eV in FWHM allowed us to observe the asymmetric broad profile of the electronic characteristic and X rays together with the hypersatellite X rays around 6 keV. This signature reflects the time-dependent screening of the nuclear charge by the negative muon and the -shell electrons, accompanied by electron side-feeding. Assisted by a simulation, this data clearly reveals the electronic - and -shell hole production and their temporal evolution during the muon cascade process.
Honda, Ryotaro*; Hasegawa, Shoichi; Hayakawa, Shuhei; Hosomi, Kenji; Imai, Kenichi; Ichikawa, Yudai; Nanamura, Takuya; Naruki, Megumi; Sako, Hiroyuki; Sato, Susumu; et al.
JPS Conference Proceedings (Internet), 26, p.023014_1 - 023014_4, 2019/11
Honda, Ryotaro*; Hasegawa, Shoichi; Hayakawa, Shuhei; Hosomi, Kenji; Ichikawa, Yudai; Imai, Kenichi; Nagamiya, Shoji; Sako, Hiroyuki; Sato, Susumu; Sugimura, Hitoshi; et al.
Physical Review C, 96(1), p.014005_1 - 014005_23, 2017/07
Times Cited Count:14 Percentile:73.31(Physics, Nuclear)Hayakawa, Masato; Suzuki, Shigeaki*; Shimoyama, Kazuhito; Umeda, Ryota; Yoshida, Eiichi; Miyakoshi, Hiroyuki
no journal, ,
no abstracts in English
Suzuki, Shigeaki*; Hayakawa, Masato; Shimoyama, Kazuhito; Umeda, Ryota; Yoshida, Eiichi; Miyakoshi, Hiroyuki
no journal, ,
We are conducting dismantling inspection of large-scale sodium component that we have been using in sodium environment for a long time. We got the cover gas area sodium deposition rate of the large tank used for several decades. As a result of examination based on the data and past findings, it was possible to derive the recommended value "1.0e-10 g/cm/s" for the cover gas region sodium adhesion rate of the plant operating in the low temperature range (150 to 200C). For disassembling large sodium equipment, it is possible to estimate and evaluate sodium adhesion amount based on this recommended value and operation history. With this evaluation, it became possible to increase the reliability of disassembly technology for safety measures and safety management related to sodium fires etc.
Nanamura, Takuya; Ichikawa, Yudai; Hayakawa, Shuhei; Yoshida, Junya; Miwa, Koji*; Honda, Ryotaro*; Akazawa, Yuya*; Yamamoto, Takeshi
no journal, ,
Hyperon-nucleon scattering experiment is one of the powerful methods for studying YN interaction. However, it is difficult due to short lifetime of hyperon. scattering experiments were performed as KEK E251 and KEK E289 in order to measure the differential cross sections. In these experiments, statistics were limited to less than 100 events and differential cross section had too large statistical errors to restrict baryon-baryon interaction models. J-PARC E40 experiment aims for measuring cross sections of scatterings with high statistics (10000 events) by overcoming difficulties of hyperon-nucleon scattering experiment. By using high rate ( 19M /spill) beam and large acceptance spectrometer, we can produce and tag large amount of beam. LH target and surrounding detector system CATCH enable us to reconstruct reactions from two body kinematics. Our experimental group completed data taking and about half of data taking by 2019 Apr. Left data taking will be performed in the end of this fiscal year.
Yomogida, Takumi; Yamada, Shinya*; Ichinohe, Yuto*; Sato, Toshiki*; Hayakawa, Ryota*; Okada, Shinji*; Toyama, Yuichi*; Hashimoto, Tadashi; Noda, Hirofumi*; Isobe, Tadaaki*; et al.
no journal, ,
Biotite is known as a host phase that retains uranium (U) in uranium deposits at Ningyo-Toge and Tono, and it is expected that the distribution of U in biotite will provide insight into the concentration and long-term immobilization of U. However, biotite contains rubidium (Rb), which interferes with X-ray fluorescence analysis, making it difficult to accurately determine the distribution of U-Rb in biotite by measurement using a conventional solid state detector (SSD). In this study, we developed a method to use a transition edge sensor (TES) as a detector in microbeam X-ray fluorescence analysis, which enables us to detect X-ray fluorescence with an energy resolution of about 20 eV and to obtain a Rb K line at 13.373 keV and a U L line at 13.612 keV can be completely separated. Therefore,the developed method enables us to accurately determine the distribution of U-Rb in biotite.
Yomogida, Takumi; Yamada, Shinya*; Ichinohe, Yuto*; Sato, Toshiki*; Hayakawa, Ryota*; Okada, Shinji*; Toyama, Yuichi*; Hashimoto, Tadashi; Noda, Hirofumi*; Isobe, Tadaaki*; et al.
no journal, ,
The reduction of uranium on biotite was studied to obtain insight into the immobilization of uranium in the environment. The chemical species of uranium in biotite were studied using a superconducting transition edge sensor and an X-ray emission spectrometer to remove interference from rubidium in biotite. As a result, the speciation of uranium in biotite collected from former uranium deposits was possible. The XANES spectra of the biotite indicated that the uranium in the biotite was partially reduced.