Refine your search:     
Report No.
 - 
Search Results: Records 1-5 displayed on this page of 5
  • 1

Presentation/Publication Type

Initialising ...

Refine

Journal/Book Title

Initialising ...

Meeting title

Initialising ...

First Author

Initialising ...

Keyword

Initialising ...

Language

Initialising ...

Publication Year

Initialising ...

Held year of conference

Initialising ...

Save select records

Journal Articles

WAZA-ARI; A Dose assessment system for patients in CT scan

Sato, Kaoru; Takahashi, Fumiaki; Endo, Akira; Ono, Koji*; Hasegawa, Takayuki*; Katsunuma, Yasushi*; Yoshitake, Takayasu*; Ban, Nobuhiko*; Kai, Michiaki*

RIST News, (58), p.25 - 32, 2015/01

The Japan Atomic Energy Agency (JAEA) are now developing WAZA-ARI for improvement of management of exposure doses due to CT examination under the joint research with the Oita University of Nursing and Health Sciences. The trial version of WAZA-ARI has been released on 21 December 2012. In trial version, users can perform dose assessment by using organ dose database based on the average adult Japanese male (JM-103) and female (JF-103) voxel phantoms and a 4 years old female voxel phantom (UFF4). The homepage of WAZA-ARI has been accessed over 1000 times per month and 28421 times by the end of September 2014. We are developing WAZA-ARI version 2 as the extension version of dose calculation functions of WAZA-ARI. WAZA-ARI version 2 will be released by the end of March 2015. In WAZA-ARI version 2. Users can upload dose calculation results to WAZA-ARI version 2 server, and utilize improvement of the dose management of patients and the optimization of CT scan conditions.

Oral presentation

Evaluation of organ doses due to CT examination by using PHITS and adult Japanese phantoms

Sato, Kaoru; Takahashi, Fumiaki; Endo, Akira; Ono, Koji*; Hasegawa, Takayuki*; Katsunuma, Yasushi*; Yoshitake, Takayasu*; Ban, Nobuhiko*; Kai, Michiaki*

no journal, , 

The Japan Atomic Energy Agency are now developing WAZA-ARI for improvement of management of exposure doses due to CT examination under the joint research with the Oita University of Nursing and Health Sciences. The trial version of WAZA-ARI has been released to the public via the home page of the National Institute of Radiological Sciences for test operation. In trial version, users can perform dose assessment against average adult Japanese by using organ dose database based on the JM-103 (male) and JF-103 (female) phantoms with average body sizes of adult Japanese. To expand functions of WAZA-ARI to enables users to perform against adult patients with other body sizes, we developed the adult Japanese phantoms with small, large and extra-large body sizes by modifying JM-103 and JF-103. By dose analysis based on these phantoms, it was concluded that organ doses per current are strongly dependent on body sizes.

Oral presentation

Development and utilization of Web-based open system for CT dose calculator, WAZA-ARIv2

Koba, Yusuke*; Nakada, Yoshihiro*; Matsumoto, Shinnosuke*; Akahane, Keiichi*; Ono, Koji*; Sato, Kaoru; Takahashi, Fumiaki; Endo, Akira; Shimada, Yoshiya*; Kai, Michiaki*

no journal, , 

While CT scan is useful for diagnosis, exposure dose derived from CT scan is relatively high. Therefore, it is important to manage patient doses and to prevent the excess exposures in young patients. JAEA developed the CT dose calculator, WAZA-ARIv2 under the collaboration research project with the National Institute of Radiological Sciences and the Oita University of Nursing and Health Sciences. In WAZA-ARIv2, users can accurately calculate exposure doses through the browser under consideration of patients information about sexes, ages (0y, 1y, 5y, 10y, 15y and adult) and fatness (small, large and extra-large body sizes). The functions of registration and database compilation of CT scan conditions and patient doses are newly added to a WAZA-ARIv2. Users can compare the distribution of patient doses in Japan with those in user's medical institution. Therefore, it will be expected that WAZA-ARIv2 can contribute the management and optimization of patients doses due to CT scan.

Oral presentation

Evaluation of the tube-voltage dependence of organ doses in X-ray CT scans using Monte-Carlo calculation

Koba, Yusuke*; Matsumoto, Shinnosuke*; Nakada, Yoshihiro*; Kasahara, Tetsuji*; Akahane, Keiichi*; Okuda, Yasuo*; Sato, Kaoru; Takahashi, Fumiaki; Yoshitake, Takayasu*; Hasegawa, Takayuki*; et al.

no journal, , 

Many of the CT devices are in Japan. It is guessed that exposure doses of Japanese derived from CT scans are higher than others. Thus, it is needed to properly manage scan conditions and exposure doses of individual patients. JAEA developed WAZA-ARI under the collaboration research project with the National Institute of Radiological Sciences (NIRS) and the Oita University of Nursing and Health Sciences. Practical use of new version WAZA-ARI named WAZA-ARIv2 began on January 30, 2015 at the web server in NIRS. In WAZA-ARIv2, users can calculate patients doses by using only standard condition (120 kV) of X-tube voltage. In recent years, CT scans at low tube voltage against pediatric patients with high radiosensitivity are increasing. In this study, spectrum of X-ray derived from CT scan at low tube voltage was examined, and was defined in "usrsors.f" file of PHITS. We reported the characteristics of X-ray and organ doses derived from CT scan at low tube voltage (80 kV).

Oral presentation

Calculating dose distribution from diagnostic CT depending on age and physique size of patients; Development of dose assessment web - system WAZA-ARI

Ono, Koji*; Koba, Yusuke*; Matsumoto, Shinnosuke*; Nakada, Yoshihiro*; Okuda, Yasuo*; Akahane, Keiichi*; Sato, Kaoru; Takahashi, Fumiaki; Yoshitake, Takayasu*; Hasegawa, Takayuki*; et al.

no journal, , 

In medical treatment, CT scan is useful diagnostic method. On the other hand, exposure doses derived from CT scans are dependent on body sizes of patients. Therefore, consideration of body sizes is essential for accurate dose assessment of individual patients. JAEA developed the CT dose calculator, WAZA-ARIv2 under the collaboration research project with the National Institute of Radiological Sciences and the Oita University of Nursing and Health Sciences. WAZA-ARIv2 enable users to accurately calculate exposure doses of patients with sexes, ages (0y, 1y, 5y, 10y, 15y and adult) and fatness (small, large and extra-large body sizes). In the future, we will be plans to add the dose calculation functions corresponding to the scan conditions at low tube voltage and multi-detector row (more 80) CT devices to WAZA-ARIv2. We reported the system and future plans of WAZA-ARIv2 corresponding to dose calculation of patients with various body sizes.

5 (Records 1-5 displayed on this page)
  • 1