Rodriguez, D.; 小泉 光生; Rossi, F.; 瀬谷 道夫; 高橋 時音; Bogucarska, T.*; Crochemore, J.-M.*; Pedersen, B.*; 高峰 潤
Journal of Nuclear Science and Technology, 57(8), p.975 - 988, 2020/08
被引用回数:4 パーセンタイル:43.68(Nuclear Science & Technology)Present safeguards verification methods of high-radioactivity nuclear material use destructive analysis techniques since passive nondestructive techniques are incapable of determining the nuclear material content. To improve this verification process, the JAEA and EC-JRC Ispra, Italy have been collaborating to develop delayed gamma-ray spectroscopy for composition analysis of the fissile nuclides as an aspect of the MEXT subsidy for improving nuclear security and the like. Multiple experiments were performed over three years using PUNITA to interrogate U and Pu samples to determine the signature from the short-lived fission products. We observed many gamma rays useful to determine the composition of a mixed nuclear material sample. Presented here are the results of these measurements with correlations to the interrogation, mass, volume, and sample homogeneity.
前田 亮; 大図 章; 呉田 昌俊; 藤 暢輔; Bogucarska, T.*; Crochemore, J.-M.*; Varasano, G.*; Pedersen, B.*
no journal, ,
原子力機構(JAEA)と欧州共同研究センター(JRC)は、核変換用MA-Pu燃料などの高線量核燃料の非破壊測定技術開発に関する共同研究を行っている。その中のDifferential Die-Away (DDA)法の不確かさの主要因は、試料内での核物質の偏在、及び試料材質によって大きく異なる中性子の減速・吸収・増倍効果である。これらを評価するため、核物質の偏在状態を模擬できる標準マトリクスを3種類の材質で作成し、核物質の偏在と中性子の減速・吸収・増倍効果を同時に調べることを可能とした。本発表では、JRC型DDA法による測定装置Pulsed Neutron Interrogation Test Assembly (PUNITA)を用いて、核物質の偏在と試料の材質が測定に与える影響を定量的に評価した結果について報告する。