Initialising ...
Initialising ...
Initialising ...
Initialising ...
Initialising ...
Initialising ...
Initialising ...
Takasaki, Koji; Sagawa, Naoki; Kurosawa, Shigeyuki*; Shioya, Satoshi; Suzuki, Kazunori; Horikoshi, Yoshinori; Mizuniwa, Harumi
JAEA-Technology 2008-028, 73 Pages, 2008/03
Recently, an imaging plate (IP) was developed. Pu analysis by an IP was studied in the JAEA Cooperative Research Scheme on the Nuclear Fuel Cycle, and the availability about detection of Pu and discrimination with radon progenies was shown. In order to apply these results to the radiation control, this research aims at evaluation of radioactivity, discrimination with radon progenies, and evaluation of AMAD by an IP. In the conventional autoradiography (ARG) by a ZnS and Polaroid film, Contamination of Pu can only be grasped by viewing. Since the digital data of the radiation and location is obtained by an IP, Pu can be detected quantitatively and radioactivity can be evaluated. As a result of this research, the image of alpha emitter on an IP is the same as that of the conventional ARG, and can be applied also to the ARG of beta and emitter. In measurement of Pu, the function of Image J (image-analysis software) was very available. Pu radioactivity was evaluated by an IP.
Morita, Suguru; Tanizawa, Teruaki*; Masayuki, Morifuji,; Takasaki, Koji; Suzuki, Hideki*; Suzuki, Kazunori; Kobayashi, Hirohide
JNC TN8410 2004-011, 83 Pages, 2004/07
In the Chemical Processing Facility (CPF), after reconstruction was completed, the examination for advanced hydrometallurgy reprocessing was carried out from December 2002 to March 2004. In this examination,Kr were discharged from the stack. Discharge ofKr was measured and estimated by the wide range radioactive Krypton detector.GM Gas monitor of the CPF stack monitor was exchanged for the wide range radioactive Krypton detector in fiscal 1994. In discharge monitoring of this examination for advanced hydrometallurgy reprocessing,Kr gas were detected for the first time by the wide range radioactive Krypton detector of CPF. In this examination, the temporary gas monitor of the conventional GM detector was installed, and the result of measurement and inventory were compared.In this report the discharge ofKr is indicated by the wide range radioactive Krypton detector. As a result of comparative evaluation, it was confirmed that the discharge monitoring by the wide range radioactive Krypton detector was appropriate.
Mizuniwa, Harumi; Takasaki, Koji; Horikoshi, Yoshinori; Suzuki, Kazunori; Shioya, Satoshi; Sagawa, Naoki; Kurosawa, Shigeyuki*
no journal, ,
no abstracts in English