Mercury flow experiments, 3; Simulation test plan under abnormal condition

Kaminaga, Masanori  ; Kinoshita, Hidetaka   ; Haga, Katsuhiro  ; Hino, Ryutaro

The Neutron Scattering Facility will be utilized for advanced fields of Material and Life science using high intensity neutron generated by spallation reaction of 1MW pulsed proton beam and mercury target. Design of spallation mercury target system is in progress to obtain high neutron performance with high reliability and safety. The target system is using mercury and contains large amount of radioactive spallation products, therefore to establish the safety of the target system, transient behaviors of the system during anticipated events should be well understood. The safety protection system and an instrumentation system for detecting abnormal conditions must be designed based on the transient behaviors in order to terminate the transient events safely. Transient behaviors of the mercury system have been analyzed by using RELAP5 code. This report presents a test plan of mercury system transient phenomena during abnormal events using a mercury experimental loop and modification of the mercury experimental loop for abnormal transient simulation tests.