Development of EC H&CD launcher components for fusion device

Takahashi, Koji; Ishitsuka, Etsuo   ; Moeller, C. P.*; Hayashida, Kazunori*; Kasugai, Atsushi; Sakamoto, Keishi; Hayashi, Kenichi*; Imai, Tsuyoshi

For the purpose to confirm the reliability of the front steering concept, tests of the front steering launcher mock-up and neutron irradiation tests of bearings for a movable mirror were carried out under the ITER conditions. The max. stress of the flexible pipes for the movable mirror was measuerd to be 60MPa, much less than the allowable stress and agree with the calculation. No degradation on the performance of bearings was obtained for the assumed fluence of ITER. The mock-up of remote steering(RS) launcher was tested and RF radiation of 0.5MW-3sec and 0.2MW-10sec over 0-10$$^{circ}$$ were performed. No degradation was obseved, either. The new launcher which has the capability of wider range rf beam steering and the corrugated square waveguide with four miter bends that yield the dog-legged structure has been designed, based on the test results. It has been fabricating for high power experiments.