Revaluation of JACS code system benchmark analyses of the heterogeneous system; Fuel rods in U+Pu nitric acid solution system

Takada, Tomoyuki; Miyoshi, Yoshinori; Katakura, Junichi

In order to perform accuracy evaluation of the critical calculation by the combination of multi-group constant library MGCL and 3-dimensional Monte Carlo code KENO-IV among critical safety evaluation code system JACS, benchmark calculation was carried out from 1980 in 1982. Some cases where the neutron multiplication factor calculated in the heterogeneous system in it was less than 0.95 were seen. In this report, it re-calculated by considering the cause about the heterogeneous system of the U+Pu nitric acid solution systems containing the neutron poison shown in JAERI-M 9859. The present study has shown that the keff value less than 0.95 given in JAERI-M 9859 is caused by the fact that the water reflector below a cylindrical container was not taken into consideration in the KENO-IV calculation model. By taking into the water reflector, the KENO-IV calculation gives a keff value greater than 0.95 and a good agreement with the experiment.