Formation of non FP plate-out High density and homegeneity ceramic thin coating onto the surface of high strength Ni-based super alloy by ion plating technique

Ishiyama, Shintaro

Al$$_{2}$$O$$_{3}$$ and ZrO$$_{2}$$ coating test was performed on the surface of Ni based super alloy by ion plateing technique and high density and homegeneity ceramic thin coating with the thichkness of 4$$mu$$m was formed on the specimen surface. 1173K-RT heat cycle and FP plat-out tests were performed with these coate specimens and no damage was found under 100 cycles and there is no plate-out onto the these specimens.