Radiated power profile observed by a tangentially viewing IR imaging bolometer in JT-60U tokamak
Konoshima, Shigeru; Peterson, B. J.*; Ashikawa, Naoko*; Miura, Yukitoshi; JT-60 Team
An IR imaging bolometer with semi-tangential views of the diverted tokamak has been designed and installed in JT-60U in 2003-2004. A 2.5 microns gold absorber foil of 9 cm
7 cm was shown to be durable during two years of operation with 1800 tokamak discharges including disruptions. Some unique analog video data from the IR camera characterizing diverted tokamak discharges have been obtained during test operation. A radiating toroidal ring has been mapped and recorded onto the foil as a clear high temperature zone at the disruption, consistent with huge core radiation measured by the resistive bolometers. Divertor radiation near the W-shaped divertor tiles of JT-60U could be identified also in the foil image as a thick line having toroidal curvature.