Report No.
 - 

Derivation of simple evaluation method for thermal shock damage on accelerator materials caused by out-of-control beam pulses and its application to J-PARC

Takei, Hayanori   ; Kobayashi, Hitoshi*

In high-intensity proton accelerator facilities, a failure of an electromagnet that steers beam pulses may result in thermal shock damage on the accelerator component by injecting an out-of-control pulse. It is important that a Machine Protection System (MPS) is appropriately designed to prevent this damage in the facilities such as Japan Proton Accelerator Research Complex (J-PARC). In this study, the simple evaluation method for the allowable injection time before the operation of the MPS was derived from the relation between the thermal stress and the yield stress of materials.The derived evaluation method was then applied to J-PARC. The allowable injection time for each component ranged from 0.1 to 70 $$mu$$s.