A Two-dimensional gas detector with individual readouts for neutron detection with a high spatial resolution and fast temporal response

Tanaka, Hiroki; Nakamura, Tatsuya  ; Yamagishi, Hideshi; Soyama, Kazuhiko  ; Aizawa, Kazuya  

A gaseous neutron-imaging detector with individual signal readouts was developed for a high spatial resolution and a fast temporal response. The system comprises a multiwire head, a gas chamber with 541 channels, fast amplifier-shaper-discriminator boards, a logic circuit for position calculation and encoding, and a fast data acquisition system. The developed prototype detector incorporating 40 $$times$$ 40 channels exhibited a temporal response of 100 ns (pulse width of the amplified signal) and a spatial resolution of 0.9 and 1.4 mm (full width at half maximum) in the x- and y-directions, respectively, with a gas pressure of 4.2-atm helium with 1.8-atm CF$$_{4}$$.