検索対象:     
報告書番号:
※ 半角英数字
 年 ~ 
 年

Experience with hydrogen addition water chemistry in the Fugen nuclear power station

None

北端 琢也*; 上田 司穂*; 高橋 秀孝; Kanesaki, Takuno*; 岩井 正樹*

Kitabata, Takuya*; Ueda, Shiho*; Takahashi, Hidetaka; Kanesaki, Takuno*; Iwai, Masaki*

None

Long term trends in water chemistry have been appeared in the Fugen after more than two years' hydrogen water chemistry: an increase of soluble Co-60 concentration and cyclic concentration change of Cr-51 in reactor water, an increase of soluble iron concentration in condensate, and acceleration of radioactivity buildup on pipeworks in the reactor cooling system. The hydrogen addition has been carried out using hydrogen produced by a water electrolysis system on the site. Protective effect of hydrogen addition on mitigating the IGSCC susceptibility of type 304 stainless steel is maintained. Hydrogen uptake by zircaloy-2 is not accelerated with the hydrogen addition.

Access

:

- Accesses

InCites™

:

Altmetrics

:

[CLARIVATE ANALYTICS], [WEB OF SCIENCE], [HIGHLY CITED PAPER & CUP LOGO] and [HOT PAPER & FIRE LOGO] are trademarks of Clarivate Analytics, and/or its affiliated company or companies, and used herein by permission and/or license.