Refine your search:     
Report No.
 - 

Evaluation of flow-induced vibration of thermometer well for JOYO

Isozaki, Kazunori ; not registered

Sodium leak accident of MONJU was caused high cycles fatigue damage of thermometer well by flow-induced vibration. It was due to the sy㎜etric vortex shedding which was occurred rear flow of thermometer well. So, Thermometer wells installed in primary and secondary heat transport systems of JOYO were evaluated of flow-induced vibration. Evaluation of flow-induced vibration of thermometer well was done checking of flow-induced vibration base on authorized design report for JOYO, evaluation of summary flow-induced vibration by natural frequency of thermometer well in sodium as cantilever models, and evaluation based on small velocity rule of ASME Code Section III Appendix N-1300. By this result, thermometer wells (12B piping of secondary cooling system) were not sattisfied requirement to avoid flow-induced vibration by small velocity rule. Therfore, Detailed vibration characteristic analysis, water flow-induced vibration test, dumping test and evaluation of structural integrity were carried out. These results, vibration amplitude of well on the tip was 0.13mm (vibration non-dimensional amplitude of 0.015) and peak stress of 2.9kg/mm$$^{2}$$ is occurred. Thermometer wells (12B piping of secondary cooling system) which occurred peak stress by flow vibration was confirmed enough to satisfy 5.3kg/mm2 of design fatigue limit.