Refine your search:     
Report No.
 - 

An experimental study of sodium aerosol detection sensitivity by laser induced breakdown spectroscopy

not registered ; not registered 

A Laser-induced breakdown spectroscopy Leak Detection technique (abbreviated LLD) of sodium is accomplished by plasmafying the sodium aerosol, and then selectively detecting the sodium specific optical spectrum. This method is potentially more reliable as a means of detecting of sodium small leakage. This report, describes test results of detection characteristics using sodium aerosol, carried out to verify the principle of LLD in addition to evaluating the response under various conditions. 0ur main objective is to examine the applicability of LLD for small sodium leakage. The main results are as follows; (1)We confirmed the principle of LLD, specifically detecting the sodium optical spectru.m. (2)The relation between LLD fluorescence intensity and sodium aerosol concentration is nearly proportional within a relatively Na concentration ranges 10$$^{-11}$$ $$sim$$ 10$$^{-8}$$ g/cm$$^{3}$$. (3)The LLD signal appeared insensitive to the effect of sampling gas flow rate, oxygen concentration, and humidity in the examined range. ln fact, a high S/N ratio is obtained for small sodium leakage, and the reliability of the leakage detection is high, because LLD showed sensitive to sodium concentration. From these results and others discussed in this report, LLD appears to be an applicable technique in small leakage detection both in terms of response and reliabilily in the leakage phase.

Acecsses

:

- Accesses

InCites™

:

Altmetrics

:

[CLARIVATE ANALYTICS], [WEB OF SCIENCE], [HIGHLY CITED PAPER & CUP LOGO] and [HOT PAPER & FIRE LOGO] are trademarks of Clarivate Analytics, and/or its affiliated company or companies, and used herein by permission and/or license.