Disassembly and removal of 50MW steam generator test facility; Disassembly and sodium removal of the large cold trap

not registered 

In May, 1999, disassembly and cleansing of sodium residues contained in the large cold trap (50MWSG) were carried out. Two cold trap units, one from the primary sodium loop and the other from the for the secondary sodium loop were disassembled and cleaned. This report describes the procedures, methods, and tasks under taken in the clean-up effort, including countermeasures for safe handling of sodium. The disassembly of the cold trap was based an information regarding similar cleansing activities external to JNC. There was also same a priori knowledge of the type and amount of sodium-laden residues. As this result, we conducted disassembly and cleansing task as provisionally planned. In fact we learned that disassembly methods for the specific components could be conducted in an aerated atmosphere. We thus gained additional disassembly and sodium cleansing experience under manageable and safe conditions.