Refine your search:     
Report No.
 - 

The rationalization design of large equipment dismantling facility (LEDF); Demonstration test on extinguishing of the cell (II)

not registered; not registered ; Matsumoto, Yoshihiro; not registered ; Kato, Noriyoshi; Miyazaki, Hitoshi; Tanimoto, Kenichi

The vaporizer in extinguishing of Large Equipment Dismantling Facility (LEDF)that cost is considering as a plan to cut down as part of a rationalization design highly. When the vaporizer is deleted, it becomes here where liquefied carbon dioxide is emitted in the direct cell, it is necessary to grasp the action and extinguishing performance of the pressure change in the cell by rapid evaporation test of the emitted liquefied carbon dioxide. So pressure action inside the fire laboratory in liquefied carbon dioxide release and a putting out the fire tests due to the combustion time of the combustible were enforced by using the general fire laboratory with Demonstration Test on Extinguishing of the cell (I) in the llth year of Heisei. However, since these tests are after laboratory without airtightness, it needs to grasp the pressure action at the time of liquefied carbon dioxide discharge under the airtight high conditions of having assumed the still more nearly actual cell. The cell (II) Demonstration Test on Extinguishing using the vessel of Sodium Leak Fire and Aerosol test rig (SOLFA-2) container inside of OEC was carried out. The results were as follows. (1)In order to grasp the pressure action of the vessel, the internal pressure of SOLFA-2 was set as -50mmH$$_{2}$$O, and emitted liquefied carbon dioxide. Consequently, the tendency for the pressure in the vessel to descend rapidly immediately after liquefied carbon dioxide discharge, and to descend gently-sloping through the process which goes up gradually after that and goes abruptly up for a short time was seen. (2)The process which goes abruptly up in an above-mentioned short time is considered to be the factors with main what some liquefied carbon dioxide emitted in the vessel changed to dry ice, and was deposited taken and sublimating surrounding heat, and evaporating again. (3)It sets to total flooding system and the average minimum temperature in the vessel becomes about -48$$^{circ}$$C, and at ...

Acecsses

:

- Accesses

InCites™

:

Altmetrics

:

[CLARIVATE ANALYTICS], [WEB OF SCIENCE], [HIGHLY CITED PAPER & CUP LOGO] and [HOT PAPER & FIRE LOGO] are trademarks of Clarivate Analytics, and/or its affiliated company or companies, and used herein by permission and/or license.