Performance of RF reference distribution system for the J-PARC linac

Kobayashi, Tetsuya; Chishiro, Etsuji; Anami, Shozo*; Michizono, Shinichiro*; Yamaguchi, Seiya*

Installation of the J-PARC linac machines (Phase I) has been almost completed and the beam commissioning will be started in December this year. The error of the accelerating field must be within $$pm$$1 degree in phase and $$pm$$1% in amplitude. Thus, high phase stability is required as an RF reference. Our objective concerning the phase stability of the reference aims at less than $$pm$$0.3 degrees. Last year the installation of the RF reference distribution system was completed. The reference signal is optically distributed to all of the low-level RF control systems by using E/O, O/E, Optical Amplifier and Optical Couplers and so on. The performance of this system was evaluated. The phase stability of $$pm$$0.06 degrees was obtained.