Refine your search:     
Report No.
 - 

Development of real-time measurement system of charge exchange recombination spectroscopy and its application to feedback control of ion temperature gradient in JT-60U

Kobayashi, Shinji*; Yoshida, Maiko; Takenaga, Hidenobu; Sakata, Shinya; Kamada, Yutaka; Sakamoto, Yoshiteru; Koide, Yoshihiko; JT-60 Team

Real-time measurement system of the ion temperature profile has been developed for the feedback (FB) control of the ion temperature gradient (grad-$$T$$$$_{rm i}$$) with the filter charge exchange recombination spectroscopy (CXRS) system in JT-60U. The rapid analytical scheme without non-linear least square fitting enables us to calculate the ion temperature with four spatial points every 10 ms using a real-time processor system. The FB control experiment of grad-$$T$$$$_{rm i}$$ has been demonstrated in ELMy H-mode plasmas by use of the neutral beam injectors having different deposition profiles as actuators. Grad-$$T$$$$_{rm i}$$ was controlled to the reference value in the ramp-down phase, however, it did not recovered in the ramp-up phase because the internal transport barrier or transport was affected by the ramp-down of grad-$$T$$$$_{rm i}$$. From the transient response analysis of grad-Ti, the increase in the central $$T$$$$_{rm i}$$ using the additional heating was required to recover the deteriorated grad-$$T$$$$_{rm i}$$.