Refine your search:     
Report No.
 - 

Quadrupole HOM damping with eccentric-fluted beam pipes

Sawamura, Masaru; Furuya, Takaaki*; Sakanaka, Shogo*; Suwada, Tsuyoshi*; Takahashi, Takeshi*; Umemori, Kensei*; Sakai, Hiroshi*; Shinoe, Kenji*

An eccentric-fluted beam pipe was proposed to damp quadrupole modes. The eccentric-flute acts as a mode converter from quadrupole to dipole. Optimized parameters permit to damp both degenerate modes of quadrupole with the eccentric-flute. External Q-values measured with a low power model agreed well with those calculated with MAFIA.

Accesses

: