Mock-up test results of monoblock-type CFC divertor armor for JT-60SA

Higashijima, Satoru; Sakurai, Shinji; Suzuki, Satoshi; Yokoyama, Kenji; Kashiwa, Yoshitoshi; Masaki, Kei; Shibama, Yusuke; Takechi, Manabu; Shibanuma, Kiyoshi; Sakasai, Akira; Matsukawa, Makoto; Kikuchi, Mitsuru

An upgrading device of JT-60 tokamak with fully superconducting coils (JT-60SA) is constructed under both the Japanese domestic program and the international program "Broader Approach". The maximum heat flux to JT-60SA divertor is estimated to 15 MW/m$$^{2}$$ for 100 s, and a monoblock-type CFC divertor armor is promising. The JT-60SA armor consists of CFC monoblocks, a cooling CuCrZr screw-tube, and a thin OFHC-Cu buffer layer, and the brazed joints are essential for the armor. Metalization inside CFC monoblock is applied for further improvement, and we confirmed again that the mock-up has heat removal capability in excess of ITER requirement. For optimization of the fabrication method and understanding of the production yield, the mock-ups corresponding to quantity produced in one furnace is also produced, and the half of the mock-ups could remove 15 MW/m$$^{2}$$ as required. This summarizes the recent progress of design and mock-up test results for JT-60SA divertor armor.