Preparation of equipment failure rate for a reprocessing facility, 2; Calculation of equipment failure rates based on the actual plant data

Ishida, Michihiko ; Inano, Masatoshi; Aoshima, Atsushi ; Suto, Toshiyuki ; Muramatsu, Ken; Ueda, Yoshinori*

Component failure rates are one of the most important inputs for PSA. Although there are many component failure rates databases for NPPs, there are few for a reprocessing plant. Therefore, in order to perform reliable PSA of a reprocessing plant, it is important to establish the failure rate database based on the actual plant maintenance data. The Tokai Reprocessing Plant (TRP) has been operating over 30 years since 1977. Maintenance records of plant components have been accumulated and compiled in the Tokai Reprocessing Plant Maintenance Support System (TORMASS). A basic study has started in the JAEA from 2005 by using the TORMASS data to contribute the development of reliable component failure rates. The outlines of the component failure estimation are summarized.