Impact of locally strong electric field on voltage holding capability for long gap electrodes in vacuum

Kojima, Atsushi; Tanaka, Yutaka*; Nakano, Shusuke*; Shimizu, Tatsuo; Akino, Noboru; Hanada, Masaya; Yamano, Yasushi*; Kobayashi, Shinichi*

JT-60 negative ion source suffered from a low voltage holding capability for long time. Recently, the voltage holding was much improved by tuning the gap lengths and minimum lengths between the acceleration grids of the ion source. This improvement is attributed to voltage holding tests of the accelerator. However, in order to design the next ion sources such as ITER and JT-60SA, further understandings and databases of vacuum insulation are required. As for the effect of the electric field, a small electrodes with small aperture which has the locally strong electric field were tested in this time. We found that the maimum electric field did not affect on the breakdown voltage, and large area of the electric filed profile decreased the breakdown voltage.