Study on efficiency of dry decontamination technique by numerical method, 2 (Joint research)

Hyakutake, Toru*; Muto, Akinori*; Sasakura, Mariko*; Minowa, Hirotsugu*; Suzuki, Kazuhiko*; Yokoyama, Kaoru; Takahashi, Nobuo; Hata, Haruhi   ; Sugitsue, Noritake

System decontamination has been generally carried out with the aim of reducing the amount of radioactive waste generated and minimizing human exposure to radiation released from nuclear fuel facilities. At the Ningyo-Toge Environmental Engineering Center, metal surfaces that are contaminated by uranium are dry decontaminated by using iodine heptafluoride (IF$$_{7}$$) as a system decontaminator. In this dry decontamination technique, a chemical reaction occurs between the uranium compound attached to the metal surface and IF$$_{7}$$. Only a few studies have been carried out on the decontamination efficiency, mechanism, level, etc. of dry decontamination techniques that use a decontamination gas. Therefore, the generalization of dry decontamination technique was assessed by a numerical method using decontamination data obtained at the Ningyo-Toge Environmental Engineering Center. A concrete analytical content is a depositing of Uranium Hexafluoride.