1 MV vacuum insulation for the ITER neutral beam injectors

Tanaka, Masanobu*; Hemsworth, R. S.*; Kuriyama, Masaaki*; Svensson, L.*; Boilson, D.*; Inoue, Takashi; Tobari, Hiroyuki; Kashiwagi, Mieko; Taniguchi, Masaki; Umeda, Naotaka; Watanabe, Kazuhiro

In the ITER neutral beam injector (NBI) for plasma heating and current drive, 40 A D$${-}$$ ions are accelerated to 1 MeV with a five-stage electrostatic accelerator. Since the accelerator is immersed in vacuum, vacuum insulation of -1 MV is one of critical issues. In order to sustain high voltage of -1 MV, minimum gap length between the accelerator and the vacuum vessel at ground potential was designed to be more than 900 mm on the basis of previous experimental data. High voltage bushing (HVB) acting as an insulating feed-through supplying electric power and cooling water to the accelerator consists of five stack insulator and each stage is designed to withstand -200 kV. A full-scale and single-stage mockup bushing was manufactured and tested to demonstrate stable voltage holding. As a result, DC -203 kV was sustained stably for 5 hours and the insulation design of HVB has been confirmed.