Development status of PPS, MPS and TS for IFMIF/EVEDA prototype accelerator

Takahashi, Hiroki  ; Kojima, Toshiyuki; Tsutsumi, Kazuyoshi; Narita, Takahiro; Nishiyama, Koichi; Sakaki, Hironao; Maebara, Sunao

Control system for the IFMIF/EVEDA prototype accelerator consists of six subsystems; Central Control System (CCS), Local Area Network (LAN), Personnel Protection System (PPS), Machine Protection System (MPS), Timing System (TS) and Local Control System (LCS). The Prototype Accelerator provides the deuteron beam with the beam power more than 1 MW, and this control system is required the high reliability and usability to perform various operation modes for beam commissioning. To satisfy these requirements, we are developing mainly PPS, MPS and TS at the beginning. This paper presents the status of hardware development of the PPS, MPS and TS.