Progress in ITER diagnostics development in Japan

Kawano, Yasunori; Kondoh, Takashi; Ishikawa, Masao; Hatae, Takaki; Yatsuka, Eiichi; Imazawa, Ryota; Ogawa, Hiroaki; Sugie, Tatsuo; Takeuchi, Masaki; Sato, Kazuyoshi; Suzuki, Satoshi; Seki, Yohji; Ono, Takehiro; Hayashi, Toshimitsu; Yamamoto, Tsuyoshi; Shimada, Takahiko; Kusama, Yoshinori

Recent progress in development of ITER diagnostic systems in Japan is presented as briefly shown below. (1) Microfission Chamber: A prototyping of vacuum feedthrough showed that the vacuum leak rate satisfies that of ITER requirement. (2) Thomson scattering (edge): A new method proposed for the measurement of anisotropic electron temperature was presented. (3) Poloidal Polarimeter: Measurement accuracy of the poloidal polarimeter was evaluated so that the accuracy of resultant current profile can satisfy the ITER measurement requirement. (4) Impurity influx monitor (divertor): By improvement of the design of equatorial port optics, expected detected light was 16 times increased in comparison with that of the previous design. (5) Divertor thermocouples (outer target): Investigation was started about the fixation method of the thermocouple on the side of divertor outer target. (6) Divertor IR thermography: Conceptual design activity was started for equatorial port optics.