Refine your search:     
Report No.
 - 

Development of the capsule assembling device at JMTR Hot Laboratory

Tayama, Yoshinobu; Kanazawa, Yoshiharu; Souzawa, Shizuo; Kawamata, Kazuo; Shizuoka, Yoshihiro; Onizawa, Satoshi; Nakagawa, Tetsuya

In the JMTR, the power ramping test is planned with high burn-up fuel as irradiation test. In the hot laboratory facilities, in accordance with the plan, as part of the development of facilities to deal with high burn-up fuel, replacing the assemble method using conventional shielding container, the system was developed that carries capsule to cell and performs assembling using capsule loading system put underwater of canal. Development has been completed in FY 2010.