Development of instrumentation for international standard

Tanimoto, Masataka ; Aoyama, Masashi; Kitagishi, Shigeru  ; Shibata, Akira ; Saito, Takashi; Nakamura, Jinichi ; Tsuchiya, Kunihiko 

The new JMTR is expected to contribute to many fields: the lifetime extension of LWRs (aging management of LWRs, development of next generation LWRs, etc.), the expansion of industry use (production of the medical radioisotope $$^{rm 99m}$$Tc, etc.) and the progress of science and technology (namely, basic research on nuclear energy). To meet a wide range of users needs, new irradiation technologies with advanced techniques have been developed. In this paper, status of the development of new measuring instruments are introduced which for neutron and $$gamma$$ irradiation tests in JMTR such as multi-paired thermocouple, rod inner pressure gauge, Self-Powered Neutron Detector (SPND) and Self-Powered Gamma Detector (SPGD).