Refine your search�ソスF     
Report No.
 - 

High-temperature X-ray imaging study of simulated high-level waste glass melt

Okamoto, Yoshihiro  ; Nakada, Masami  ; Akabori, Mitsuo; Komamine, Satoshi*; Fukui, Toshiki*; Ochi, Eiji*; Nitani, Hiroaki*; Nomura, Masaharu*

The molten state of the simulated high-level waste glass and the behavior of ruthenium element in the melt were investigated by using synchrotron radiation based X-ray imaging technique. Melting, generating and moving of bubbles, condensation and sedimentation of ruthenium element were observed dynamically in continuous 12-bit gray-scale images from the CCD camera. The existence of ruthenium in the X-ray CCD image was emphasized over the energy of Ru K-absorption edge. X-ray intensity was obtained easily by digitalizing gray-scale values in the image. Position sensitive imaging X-ray absorption fine structure (XAFS) measurement was performed to clarify the chemical state of ruthenium element in the melt.

Accesses

:

- Accesses

InCites™

:

Altmetrics

: