Refine your search:     
Report No.
 - 

$$gamma$$-ray and neutron area monitoring system of linear IFMIF prototype accelerator building

Takahashi, Hiroki  ; Kojima, Toshiyuki; Narita, Takahiro; Tsutsumi, Kazuyoshi; Maebara, Sunao; Sakaki, Hironao; Nishiyama, Koichi

For radiation safety of the Linear IFMIF Prototype Accelerator, $$gamma$$-ray and neutron area monitoring system are designed. This system monitors and records the measured data by using both a supervisory board in the access room and central control system. The interlock signals are sent to Personnel Protection System (PPS) and Machine Protection System (MPS) when the integrated dose value exceeds a threshold value. After receiving them, the PPS and the MPS immediately inhibit the beam operation for secure radiation safety. This monitoring system is designed to achieve a high reliability for data transfer using hardwired interlock signals and the performance of data communication between area monitoring system and control system.

Accesses

:

- Accesses

InCites™

:

Percentile:0.01

Category:Nuclear Science & Technology

Altmetrics

: