Influence of core winding tension and ribbon quality on the MA core RF characteristics

Nomura, Masahiro  ; Schnase, A.*; Shimada, Taihei ; Tamura, Fumihiko   ; Yamamoto, Masanobu   ; Hara, Keigo*; Hasegawa, Katsushi*; Omori, Chihiro*; Toda, Makoto*; Yoshii, Masahito*

During the development of Magnetic Alloy (MA) cores for RF cavities, the core shunt impedance was increased by lowering a core winding tension to improve the electrical insulation between MA ribbon layers. The lower winding tension reduced the core filling factor. The core shunt impedance might be reduced according to the core filling factor reduction. We study the influence of improving the electrical insulation and lowering the core winding tension on the core shunt impedance.