Refine your search:     
Report No.
 - 

Development of DC-1MV insulation transformer for ITER Project

Watanabe, Kazuhiro; Yamanaka, Haruhiko; Yamaguchi, Kohei*; Kadowaki, Makoto*; Ichimura, Satoshi*

An insulation transformer for ITER Project is required to supply AC power source for ion source and extractor power supplies located on DC -1 MV insulated deck. A mockup model for the insulation transformer has been developed to verify the insulation capability of DC -1 MV and assembling procedure. It has been successfully demonstrated for sufficient insulation of higher than DC -1 MV through dielectric tests.