Refine your search�ソスF     
Report No.
 - 

Development of Self Powered Gamma Detector (SPGD) with lead emitter

Shibata, Akira ; Takeuchi, Tomoaki   ; Otsuka, Noriaki ; Saito, Takashi; Onoda, Shinobu; Oshima, Takeshi; Tsuchiya, Kunihiko 

The big tsunami wave caused by the Great East Japan Earthquake triggered station black out of the Fukushima Daiichi Nuclear Power Plant. The schedule until ending of the decommission is shown in the guidance from Japanese government. But the dose rate in the reactor vessel is quite high and it is not possible to specify the position of melted fuel debris by visual inspection. That is one of the most important issues in this process. This report describes the development of Self Powered Gamma Detector (SPGD) for the purpose to specify the position of melted fuel debris and situation in the reactor by measuring $$gamma$$ rate in the reactor of the Fukushima Daiichi Nuclear Power Plant. The $$gamma$$ irradiation examinations by changing the parameter of emitters figure were performed and the dependency of SPGD output on emitter shape was summarized.