Electrically insulated MLI and thermal anchor

Kamiya, Koji; Furukawa, Masato; Hatakenaka, Ryuta*; Miyakita, Takeshi*; Murakami, Haruyuki; Kizu, Kaname; Tsuchiya, Katsuhiko; Koide, Yoshihiko; Yoshida, Kiyoshi

The thermal shield of JT-60SA is kept at 80 K and will use the Multi Layered Insulator (MLI) to reduce radiation heat load to the superconducting coils at 4.4 K from the cryostat at 300 K. Due to plasma pulse operation, the MLI is affected by eddy current in toroidal direction. The MLI is designed to suppress the current by electrically insulating every 20 degree in the toroidal direction by covering the MLI with polyimide films. In this paper, two kinds of designs for insulated MLI are proposed focusing on a way to overlap MLI. A boil-off calorimeter method and temperature measurement has been performed to determine the thermal performance of MLI. The design of electrical insulated thermal anchor between the toroidal field (TF) coil and the thermal shield is also explained.