Deterministic parsing model of the compound biological effectiveness (CBE) factor for intracellular $$^{10}$$boron distribution in boron neutron capture therapy

Ishiyama, Shintaro

Deterministic parsing model of Compound Biological Effectiveness (CBE) in BPA-mediated BNCT was proposed for intra-organ $$^{10}$$B distribution. In defining the biological effects of the $$^{10}$$B($$n$$,$$alpha$$)$$^{7}$$Li neutron capture reaction, CBE factor model is expressed; CBE = CBE$$_{0}$$ ($$r_{0}$$ $$<$$ $$r$$ or $$N$$ $$<$$ $$N_{rm th}$$) and CBE = CBE$$_{0}$$ + $$F$$[1-($$N$$/$$N_{rm th}$$)(-2/3)][1-($$N$$/$$N_{rm th}$$)(-1/3)] ($$r_{0}$$ $$>$$ $$r$$ or $$N$$$$>$$$$N_{rm th}$$) Where $$r$$ and $$r_{0}$$ are distance between boron atoms and $$alpha$$ range, $$N$$ and $$N_{rm th}$$ are boron concentration and threshold of $$^{10}$$B concentration in tissues and tumour, CBE$$_{0}$$ and $$F$$ are obtained as 0.5 and 8 for normal tissues and for tumour, respectively. $$N$$ and $$N_{rm th}$$ are evaluated the bio-distribution of $$^{10}$$B in normal tissues and tumour after injection and the CBE factor for normal tissues and tumor approximately within + 0.12 to -0.54% high accuracy.