Improvement of the position monitor using white light interferometer for measuring precise movement of compact ERL superconducting cavities in cryomodule

Sakai, Hiroshi*; Enami, Kazuhiro*; Furuya, Takaaki*; Sato, Masato*; Shinoe, Kenji*; Umemori, Kensei*; Sawamura, Masaru; Cenni, E.*; Aoto, Tomohiro*; Hayashi, Kyohei*; Kanzaki, Tsutomu*

Alignment of superconducting cavities is one of the important issues for linear collider and/or future light source like ERL and X-FEL. To measure the cavity displacement under cooling to liquid He temperature more precisely, we newly developed the position monitor based on the measurement of the interference of light between the measurement target and the reference point. We applied this monitor to the main linac cryomodule of Compact ERL (cERL) and successfully measured the displacement during 2 K cooling with the resolution of 10 $$mu$$m.