Mechanical vibration search of compact ERL main linac superconducting cavities in cryomodule

Sato, Masato*; Enami, Kazuhiro*; Furuya, Takaaki*; Michizono, Shinichiro*; Miura, Takako*; Qiu, F.*; Sakai, Hiroshi*; Shinoe, Kenji*; Umemori, Kensei*; Sawamura, Masaru; Cenni, E.*

For the main linac of ERL, high loaded Q (QL) operation is desirable to reduce the input generator power. In such operation mode, the suppression of the micophonics is important to stabilize RF amplitude and phase. One of reasons which causes microphonics is mechanical vibration, which changes the cavity frequency. The vibrations of the cavities, the cryomodule and the floor were investigated and compared with the microphnics data taken during cERL operation.