Key aspects of the safety study of a water-cooled fusion DEMO reactor

Nakamura, Makoto; Tobita, Kenji; Someya, Yoji; Tanigawa, Hisashi; Gulden, W.*; Sakamoto, Yoshiteru; Araki, Takao*; Watanabe, Kazuhito*; Matsumiya, Hisato*; Ishii, Kyoko*; Uto, Hiroyasu; Takase, Haruhiko; Hayashi, Takumi; Satou, Akira ; Yonomoto, Taisuke ; Federici, G.*; Okano, Kunihiko*

Key aspects of the safety study of a water-cooled fusion DEMO reactor is reported. Safety requirements, dose target, DEMO plant model and confinement strategy of the safety study are briefly introduced. The internal hazard of a water-cooled DEMO, i.e. radioactive inventories, stored energies that can mobilize these inventories and accident initiators and scenarios, are evaluated. It is pointed out that the enthalpy in the first wall/blanket cooling loops, the decay heat and the energy potentially released by the Be-steam chemical reaction are of special concern for the water-cooled DEMO. An ex-vessel loss-of-coolant of the first wall/blanket cooling loop is also quantitatively analyzed. The integrity of the building against the ex-VV LOCA is discussed.