Radioactivity leak accident at the hadron experimental facility and the reformation of the safety management system in J-PARC

Ishii, Tetsuro  

Radioactivity leak accident occurred at the Hadron Experimental Facility of J-PARC revealed serious problems on safety organization and emergency actions as well as problems on hardware. We have reviewed safety management system entirely and reformed it as follows. (1) The responsibility of facility manager and command line was clearly defined. (2) Radiation safety review system was reinforced. (3) "Alert Status" between "Standard Status" and "Emergency Status" was introduced for gathering of responsible personnel and integration and sharing information. (4) Criteria and procedures for actions in emergency and notification were clarified.