Refine your search�ソスF     
Report No.
 - 

Study on model development for liquid accumulation in steam generator U-Tube, 4; Data analysis on differential pressure

Yamazaki, Kohei*; Otake, Hiroyasu*; Hasegawa, Koji*; Hasebe, Yoshiaki*; Yamaji, Tatsuya*; Koizumi, Yasuo; Onuki, Akira*; Nishi, Hiroaki*

Experiments of counter-current two-phase flow of upward steam flow and condensing downward film flow in a pipe were performed. The experiments were intended to examine water accumulation in steam generator U-tubes during intermediate and small break loss-of-coolant accidents of a pressurized water reactor. The inner diameter and the length of a test flow channel used in the experiments were 18 mm and 4 m, respectively. In the present experiments, the test tube was changed from the polycarbonate tube that had large heat transfer resistance to a bras tube that had low heat transfer resistance so as to cover wide range for the condensing film flow rate. Since the vapor velocity was large in present experiments, the condensate film flowed upward and flowed out from the top outlet of the test tube. A flow state in the test tube was upward annular two-phase flow. Pressure drop between the inlet ad the outlet of the test tube was well expressed with the Lockhart-Martinelli correlation for the two-phase flow pressure drop. The experimental results suggested to promise the possibility for data accumulation in the future.

Accesses

:

- Accesses

InCites™

:

Altmetrics

:

[CLARIVATE ANALYTICS], [WEB OF SCIENCE], [HIGHLY CITED PAPER & CUP LOGO] and [HOT PAPER & FIRE LOGO] are trademarks of Clarivate Analytics, and/or its affiliated company or companies, and used herein by permission and/or license.