Report No.
 - 

Proximity factor on transformation from subsurface to surface flaw

Hasegawa, Kunio*; Li, Y. ; Serizawa, Ryosuke*; Kikuchi, Masanori*; Lacroix, V.*

If subsurface flaws are detected that are close to component free surfaces, flaw-to-surface proximity rule is used to determine whether the flaws should be treated as subsurface flaws as is, or transformed to surface flaws. However, specific factors for the proximity rules on transforming subsurface to surface flaws differ among fitness-for-service codes. The objective of the paper is to reveal the proximity factor from the stress intensity factor interaction between the subsurface flaw and the free surface.