Refine your search:     
Report No.
 - 

Development of active control technology for impurities in coolant helium using High Temperature Engineering Test Reactor (HTTR)

Hamamoto, Shimpei  ; Nemoto, Takahiro; Sekita, Kenji; Saito, Kenji 

The decarburization may take place depending on the chemical impurity composition in helium gas used as the primary coolant in High-Temperature Gas-cooled Reactors, and will significantly reduce the strength of the alloy. The ability to remove impurities by a helium purification system was designed according to the predicted generation rate of impurities so as to make the coolant become the carburizing atmosphere. It has been confirmed that the coolant becomes the carburizing atmosphere during the operation period of the High Temperature engineering Test Reactor (HTTR). However, it is necessary to consider changes of generation rates of impurities since lifetime of commercial reactor is longer than the life of the HTTR. To avoid the influence of the change of generation rate, the control of removal efficiency of impurity in the helium purification system was considered in this study. To reform the decarburizing into the carburizing atmosphere, it is effective to increase the H$$_{2}$$ and CO concentration in the coolant helium. By controlling the efficiency of the Cooper Oxide Trap (CuOT), it is possible to increase the H$$_{2}$$ and CO concentrations. Therefore, an experiment was carried out by injecting the gas mixture of H$$_{2}$$ and CO into the existing purification system of HTTR to investigate the dependencies of temperature and impurity concentration on the removal efficiency of CuOT. The experimental results are described as the following, (1) By adjusting the temperature of helium at the CuOT within a range from 110$$^{circ}$$C to 50$$^{circ}$$C, it is possible to reduce the removal efficiency of H$$_{2}$$ sufficiently. (2) Temperature change of helium gas in the CuOT is sufficiently reduced by the cooler located at the downstream of the CuOT, which does not affect the primary cooling system of HTTR. As the results, the applicability of removal efficiency control of CuOT was verified to improve the decarburizing atmosphere for the actual HTGR system.

Acecsses

:

- Accesses

InCites™

:

Altmetrics

:

[CLARIVATE ANALYTICS], [WEB OF SCIENCE], [HIGHLY CITED PAPER & CUP LOGO] and [HOT PAPER & FIRE LOGO] are trademarks of Clarivate Analytics, and/or its affiliated company or companies, and used herein by permission and/or license.