Study on improvement of safety for accident conditions in spent fuel pool, 11; Evaluation of cooling characteristics of SFP spray and alternative water injection with MAAP code

Nishimura, Satoshi*; Satake, Masaaki*; Soga, Shota*; Nishi, Yoshihisa*; Kaji, Yoshiyuki  ; Nemoto, Yoshiyuki  

Using the severe accident code MAAP5.03, simulation of the loss of cooling function accident in spent fuel pool was conducted and cooling performance of the emergency cooling systems such as spray or water inlet was evaluated.