A Remote-operated system to map radiation dose in the Fukushima Daiichi primary containment vessel

Nancekievill, M.*; Jones, A. R.*; Joyce, M. J.*; Lennox, B.*; Watson, S.*; Katakura, Junichi*; Okumura, Keisuke ; Kamada, So*; Kato, Michio*; Nishimura, Kazuya*

We are developping a submersible ROV system, coupled with radiation detectors aimed at mapping the interior of the reactors at the Fukushima Daiichi Nuclear Power Station. To map the $$gamma$$-ray intensity environment a cerium bromide (CeBr$$_{3}$$) inorganic scintillator detector sensitive to $$gamma$$-rays has been incorporated into the ROV to measure $$gamma$$-ray intensity and identify radioactive isotopes. The ROV is a cylindrical shape with a diameter of about 150 mm, and it have two end caps of five pumps each allowing control of the ROV in 5 degree of freedom. It is possible to directly replace the CeBr$$_{3}$$ detector with a single crystal chemical vapour deposition (CVD) neutron detector with a $$^{6}$$Li convertor foil that is capable of mapping the thermal neutron flux.