Development and validation of evaluation method on hypothetical total instantaneous flow blockage in sodium-cooled fast reactors and its application to a middle size SFR

Fukano, Yoshitaka  

An evaluation on the consequences of a hypothetical total instantaneous flow blockage at the coolant inlet of an SA (HTIB) using SAS4A code was also performed in the past study. SAS4A code was further developed by implementing analytical model of power control system in this study. An evaluation on the consequences of HTIB in Monju by this developed SAS4A code was performed. It was clarified by the analyses considering power control system that the reactor would be safely shut down by the plant protection system triggered by either of 116 percent over power or delayed neutron detector trip signals. Therefore the conclusion in the past study that the consequences of HTIB event would be much less severe than that of unprotected loss-of-flow event was strongly supported by this study. Furthermore SAS4A code was newly validated using an in-pile experiment which simulated HTIB events. The validity of SAS4A application to safety evaluation on the consequence of HTIB was further enhanced in this study.