Development of $$gamma$$-ray directional radiation dose detector with good efficiency for field survey

Yamamori, Ryo*; Kobayashi, Hikaru*; Honta, Shohei*; Yoshino, Hiroshi*; Nozaki, Atsuo*; Ichijo, Yusuke*; Hijikata, Yoshio*; Yoshida, Hiroko*; Furuta, Takuya   

Understanding radiation field is important to predict radiation dose rate in newly constructing buildings in an area widely contaminated by radioactive nuclei. Directional spectra of the radiations are important to consider the shielding effect of the building. We adopts a method to measure the directional spectra by adopting a plate of lead collimator in front of the scintillator and subtract the values from the spectra measured without lead collimator. We investigated a possible weight saving detection system having sufficient detection efficiency. The investigation was carried out for the condition of the collimator radius ($$phi$$ = 10, 15, 20 cm) and the distance between collimator and detector ($$ell$$ = 1, 3, 5 cm). We found that three combinations satisfied the 90$$^{circ}$$ field view and the detection efficiency became better with larger collimator radius. On the other hand, larger collimator radius indicate heavier detection system. Therefore, we developed an optimum detection system for field survey with the 15 cm diameter plate (10kg), the scintillator (3.4kg), and the folder (1.0kg).