Refine your search:     
Report No.
 - 

Struggle to suppress radio-activation due to multi-turn charge exchange beam injection with stripper foil and its issues

Yoshimoto, Masahiro  ; Kato, Shinichi; Okabe, Kota  ; Harada, Hiroyuki  ; Kinsho, Michikazu  

It is key issue to reduce the level of the radio-activation of the devices in high power proton accelerator, to achieve MW class high power beam operation. The 3 GeV Rapid Cycling Synchrotron (RCS) of the Japan Proton Accelerator Research Complex (J-PARC) adopted a beam collimation system which aims to localize the beam loss at the collimators and to reduce the level of residual doses at the other devices. However, relatively high residual doses are detected in not only the beam collimator area but also a vicinity of the stripper foil. The results of previous work, measurements of the detailed residual dose distribution and simulations of the radio-activation by the PHITS, indicate that the high level residual dose around the stripper foil is caused by secondary particles due to nuclear reaction at the foil. In order to suppress the secondary particles from foil, we try hard to reduce the number of foil hitting particles during the beam injection period. As a result, the level of the radio-activation around the foil can be decreased. At the same time, new beam loss monitor to detect the secondary particles from the foil is developed. In this presentation, we report the secondary particles detections and estimations of number of the foil hitting particles. In addition, we discuss the reduction of the radio-activation.

Accesses

:

- Accesses

InCites™

:

Altmetrics

:

[CLARIVATE ANALYTICS], [WEB OF SCIENCE], [HIGHLY CITED PAPER & CUP LOGO] and [HOT PAPER & FIRE LOGO] are trademarks of Clarivate Analytics, and/or its affiliated company or companies, and used herein by permission and/or license.