Level 1 PRA for design works of external vessel storage tank in advanced loop-type sodium-cooled fast reactor

Yamano, Hidemasa   ; Naruto, Kenichi*; Kurisaka, Kenichi ; Nishino, Hiroyuki  

Spent fuels are kept in an external vessel storage tank (EVST) filled with sodium for fuel handling in sodium-cooled fast reactors. This study performed Level 1 PRA for the EVST designed in an advanced loop-type reactor in order to identify dominant accident sequences leading to fuel failure and to quantify fuel damage frequency.