RELAP5 modeling of the HTTR-GT/H$$_{2}$$ secondary system and turbomachinery

Humrickhouse, P. W.*; Sato, Hiroyuki  ; Imai, Yoshiyuki  ; Sumita, Junya ; Yan, X. 

This work describes the development of a RELAP5-3D model of the HTTR-GT/H$$_{2}$$ plant secondary system. The RELAP5-3D model presently includes detailed models of several of the heat exchangers in the secondary system as well as the turbomachinery, which includes two compressors and two gas turbines connected to a common shaft and motor. The predictions of the model agreed well to design parameters in both sole power generation and hydrogen co-generation modes in most instances. Both the turbomachinery and heat exchanger models rely on extensive customization via RELAP5-3D control variables, and these implementations are outlined in detail. Potential improvements to the RELAP5-3D turbine model are discussed.